Combination two-gang/four square box. Eccentric knockouts, non-metallic and non-conductive.1/2", 3/4", 1" KNOCK-OUTSCu In Cap=38DOUBLE GANGENTUnit: EA ...
Combination two-gang/four square box. Eccentric knockouts, non-metallic and non-conductive.1/2", 3/4", 1" KNOCK-OUTSCu In Cap=38DOUBLE GANGENTUnit: EA
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.. UL listed,...
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.. UL listed, RoHS Compliance.Size In=1-1/2SCHEDULE 40Unit: EA
Safe, non-conductive, takes standard covers and accessories. For through terminations. With detachable mounting feet. 19 cu-in capacity.Size In=1SINGLE GANGTYPE FSCUnit: EA ...
Safe, non-conductive, takes standard covers and accessories. For through terminations. With detachable mounting feet. 19 cu-in capacity.Size In=1SINGLE GANGTYPE FSCUnit: EA
Round old work box with 4 integral swing clamps. Three zip mount retainers. High-temperature resistant. 4-1/4 in Dia x 2-3/4 in D. UL listed."ZIP BOX BLUE"Cu In Cap=18PVCROUND - OLD WORKUnit: EA ...
Round old work box with 4 integral swing clamps. Three zip mount retainers. High-temperature resistant. 4-1/4 in Dia x 2-3/4 in D. UL listed."ZIP BOX BLUE"Cu In Cap=18PVCROUND - OLD WORKUnit: EA
Non-metallic ABS material is lightweight, paintable and easy to handle. Recessed low profile design provides ample room behind dry wall and between studs to accommodates cable bend requirements....
Non-metallic ABS material is lightweight, paintable and easy to handle. Recessed low profile design provides ample room behind dry wall and between studs to accommodates cable bend requirements. Hides the wires, cables, cords and plug heads used with flat panel display installations. Has a two gang low voltage opening and a universal one gang opening for an outlet or switch box (boxes, devices and plates not included). 4 swing out clamps lock the plate securely to the wall, horizontal or...
Rigid non-metallic Type LB conduit body. For easy access and pulling of wires through conduit run. For use with Schedule 40 non-metallic solvent weld fittings. Will not rust or corrode. With...
Rigid non-metallic Type LB conduit body. For easy access and pulling of wires through conduit run. For use with Schedule 40 non-metallic solvent weld fittings. Will not rust or corrode. With textured lid and foam-in-place gasket. Hubs are not threaded. ULListed, RoHS Compliance.Size In=1-1/2TYPE LBSCHEDULE 40/80Unit: EA
For easy access and pulling of wires through conduit run. For use with Schedule 40/80 non-metallic solvent weld fittings. Will not rust or corrode.Size In=2TYPE TSCHEDULE 40/80Unit: EA ...
For easy access and pulling of wires through conduit run. For use with Schedule 40/80 non-metallic solvent weld fittings. Will not rust or corrode.Size In=2TYPE TSCHEDULE 40/80Unit: EA
Carlon Terminal Adapter, 1/2 in Trade, MPT x Socket Connection, PVC, Gray, 1.31 in Length, 1.04 in Diameter, Suitable for: SCH 40 and 80 Rigid ConduitsUnit: PK 10
Two gang blank rise. Carlon blue color. PVC - NON-METALLICBLANKUnit: EA
Offers same chemical resistance as carbon non-metallic conduit for a complete, corrosion-resistant system. UV-resistant for use in direct sunlight. Use in accordance with conduit spacing...
Offers same chemical resistance as carbon non-metallic conduit for a complete, corrosion-resistant system. UV-resistant for use in direct sunlight. Use in accordance with conduit spacing requirements per NEC. Each clamp requires 2 screws, 2 nuts and 2 washers. Gray clamps for standard conduit.Size In=3/4PVC/NON-METALLICTWO HOLESUnit: BAG20
The Carlon SuperBlueΓäó hard shell boxes combine the features of the hard shell thermoset box and the thermoplastic PVC style box to create a new rigid non-metallic wiring box. Molded out of...
The Carlon SuperBlueΓäó hard shell boxes combine the features of the hard shell thermoset box and the thermoplastic PVC style box to create a new rigid non-metallic wiring box. Molded out of specially formulated thermoplastic material, Carlon SuperBlue boxes are so strong they won't crack or break, even in extreme environments. So rigid, they resist flexing and hold their shape even under the worst conditions. They provide the largest wirefill capacity in their class and come with molded-in...
Innovative one-piece quick connect design for fast and easy installation. Suitable for damp locations. No glue or cement needed. Carlon Standard Blue. Concretetight when used with appropriate...
Innovative one-piece quick connect design for fast and easy installation. Suitable for damp locations. No glue or cement needed. Carlon Standard Blue. Concretetight when used with appropriate ENT."ENT"Size In=1/2ELECTRICAL - NON-METALLICONE PIECEUnit: EA
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.. UL listed, RoHS Compliance.Size In=1SCHEDULE 40Unit: EA
With captive nails and ten integral clamps, three top and bottom, two each side. Suitable for masonry walls. 4 in x 4 in square. UL listed.DEEP - 2-5/8" DEPTHCu In Cap=32SQUAREUnit: EA ...
With captive nails and ten integral clamps, three top and bottom, two each side. Suitable for masonry walls. 4 in x 4 in square. UL listed.DEEP - 2-5/8" DEPTHCu In Cap=32SQUAREUnit: EA
For use with non-metallic solvent weld fittings. Non-conductive, impact, corrosion and sunlight-resistant. UL listed E35297.SCHEDULE 40 - WITH BELL ENDSize In=1/2PVC - 45 DEGREESTANDARD RADIUSUnit:...
For use with non-metallic solvent weld fittings. Non-conductive, impact, corrosion and sunlight-resistant. UL listed E35297.SCHEDULE 40 - WITH BELL ENDSize In=1/2PVC - 45 DEGREESTANDARD RADIUSUnit: EA
Weatherproof for use with non-metallic wiring systems. Non-conductive, non-corrosive and impact-resistant for a safe, long, service-free life in exposed applications. Install in accordance with NEC...
Weatherproof for use with non-metallic wiring systems. Non-conductive, non-corrosive and impact-resistant for a safe, long, service-free life in exposed applications. Install in accordance with NEC and local codes. Three 1/2 in threaded ports, one on each end and one in the back. UL listed.Color=GraySINGLE GANG - T-BOX - THREADEDPVC/NON-METALLIC - RECTANGULARWEATHERPROOFUnit: EA
Spring metal mounting brackets. Fixture rating limit of 10 lb. Heat-resistant. 3-1/2 in Dia round old/new work box base, ears and snap-in bracket. UL listed."SUPER BLUE"Cap Cu In=14.5PVC -...
Spring metal mounting brackets. Fixture rating limit of 10 lb. Heat-resistant. 3-1/2 in Dia round old/new work box base, ears and snap-in bracket. UL listed."SUPER BLUE"Cap Cu In=14.5PVC - ROUNDOLD/NEW WORKUnit: EA
Offers same chemical resistance as carbon non-metallic conduit for a complete, corrosion-resistant system. UV-resistant for use in direct sunlight. Use in accordance with conduit spacing requirements per NEC. Each clamp requires 2 screws, 2 nuts and 2 washers. Gray clamps for standard conduit.Size In=1PVC/NON-METALLICTWO HOLESUnit: PK 5
Lightweight design and durable plastic. Listed for masonry walls. Safe to install and will never rust or corrode. Includes nails for quick, easy installation. 22 cu-in rigid wall. 3-7/8 in x 2-3/8...
Lightweight design and durable plastic. Listed for masonry walls. Safe to install and will never rust or corrode. Includes nails for quick, easy installation. 22 cu-in rigid wall. 3-7/8 in x 2-3/8 in x 3-3/4 in. UL listed."SUPER BLUE"Cu In Cap=22SINGLE GANGNEW WORKUnit: EA
For use with non-metallic solvent weld fittings. Non-conductive, impact, corrosion and sunlight-resistant. Manufactured to NEMA TC-2, Federal specification WC1O94A and UL 651 specifications. UL 651...
For use with non-metallic solvent weld fittings. Non-conductive, impact, corrosion and sunlight-resistant. Manufactured to NEMA TC-2, Federal specification WC1O94A and UL 651 specifications. UL 651 Listed to the NEC by the ETL, UL listed.SCHEDULE 40Size In=2-1/2Radius\In=24PVC 90 DEGREESPECIAL RADIUSUnit: EA
High impact lightweight round blank PVC cover for 4 in round boxes to make junctions. UL listed."ZIP BOX BLUE"Dia In=4Color=BlueROUND BLANK - PVCUnit: EA ...
High impact lightweight round blank PVC cover for 4 in round boxes to make junctions. UL listed."ZIP BOX BLUE"Dia In=4Color=BlueROUND BLANK - PVCUnit: EA
Drill 5/16 in hole with masonry bit and tap in with hammer.Trade Size In=1/2NYLON - MASONRYUnit: BAG 5
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.Size...
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.Size In=1-1/4SCHEDULE 40Unit: EA
For use with non-metallic solvent weld fittings. Non-conductive, impact, corrosion and sunlight-resistant.Size In=1/2Schedule=80PVC - 90 DEGREESTANDARD RADIUSUnit: EA ...
For use with non-metallic solvent weld fittings. Non-conductive, impact, corrosion and sunlight-resistant.Size In=1/2Schedule=80PVC - 90 DEGREESTANDARD RADIUSUnit: EA