Zinc die-cast. Removable steel cover facilitates wire pulling. Use to connect EMT conduit together at a 90 deg bend. Tray box.Unit: EA
Zinc die-cast. Use to join two lengths of EMT conduit together. UL approved.Unit: EA
Unit: PK150
Die-cast of high strength zinc alloy. Use to secure SE/SEU cable to a metal enclosure. Use to connect UF cable to a waterproof box with a threaded hub.Unit: BAG 1
High-impact thermoplastic. Flame retardant to 105 deg C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire...
High-impact thermoplastic. Flame retardant to 105 deg C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL listed and CSA approved.Unit: EA
Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL listed and CSA...
Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL listed and CSA certified.Unit: EA
Zinc die-cast. Use to connect EMT conduit to steel outlet box, load center or other metal enclosure. UL approved.Unit: EA
Halex Hole Strap, 3/8 in Trade, Steel, 6 in Length, 3-1/2 in Width, 3-3/4 in HeightUnit: BX200
Indoor or outdoor use. Use to secure rigid or IMC conduit to wood, masonry or similar surfaces where greater load bearing is required. UL Listed, CSA Approved.Unit: BX100
Halex Conduit Hanger, Steel, Suitable for: 1/2 in EMT or RGD ConduitsUnit: BAG5
Indoor or outdoor applications. Use to secure PVC conduit to wood, masonry or similar surface. Bulk packed.Unit: EA
To connect EMT conduit together to allow for 90 deg bends. UL listed.Unit: EA
Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure.Unit: EA
Halex Reducing Washer, Steel, 0.87 in ID, 1-3/4 in OD, 0.0315 in ThicknessUnit: EA
Aluminum, indoor or outdoor. Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. With cover and gasket. UL...
Aluminum, indoor or outdoor. Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. With cover and gasket. UL Approved.Unit: EA
Zinc die-cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. UL listed.Unit: BAG 1
Zinc die-cast. Use to join two lengths of EMT conduit together. UL approved.Unit: BAG 5
Indoor or outdoor applications. To support EMT conduit.Unit: BX 50
Zinc die-cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway...
Zinc die-cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. UL and CSA approved.Unit: BAG
Zinc die-cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.Unit: BAG 1
Indoor or outdoor. Wire size fits 8 to 4 AWG. Use to secure the grounding wire to a 1/2 in through 1 in pipe. Bronze, bagged. UL listed.Unit: EA
Multi-piece. Zinc die-cast. Use to connect liquid-tight conduit to a steel outlet box or other metal enclosure or hub. UL listed. Bulk packed.Unit: EA
Zinc die-cast. Rounded surface prevents damage to insulation. Thermoplastic liner rated at 150 deg F. Indoor or outdoor use. Use with locknut to terminate service conduit to a cabinet. Lug provided...
Zinc die-cast. Rounded surface prevents damage to insulation. Thermoplastic liner rated at 150 deg F. Indoor or outdoor use. Use with locknut to terminate service conduit to a cabinet. Lug provided for bonding jumper to a neutral bus bar. UL listed and CSA certified.Unit: BAG 1
Zinc die-cast. Indoor or outdoor applications. Use to reduce the entry size of a run of threaded conduit. UL listed.Unit: BAG 1