The Selkirk Chimney System (SCS) is ideal for venting residential heating appliances burning wood, 2-oil and natural and LP gas. They have been specifically designed for today's modern,...
The Selkirk Chimney System (SCS) is ideal for venting residential heating appliances burning wood, 2-oil and natural and LP gas. They have been specifically designed for today's modern, high-efficiency "airtight" wood stoves. They are designed for gravity (natural draft), non-positive internal pressure venting only. The SCS is usable on any appliance having a power burner (such as an oil furnace) if that appliance operates with neutral or negative draft at its outlet.Unit: EA
Designed to fit on the round chimney pipe just above the roof flashing. The upper edge of the collar should be waterproofed with plastic sealer to prevent any water from leaking between the collar...
Designed to fit on the round chimney pipe just above the roof flashing. The upper edge of the collar should be waterproofed with plastic sealer to prevent any water from leaking between the collar and chimney pipe. Part is tightened with screws or tabs after proper positioning.Unit: EA
Double wall stove pipe is a connector pipe that links wood stoves to insulated chimneys. This system features a black aluminized steel outer casing and heavy-gauge stainless steel inner liner. 1/4...
Double wall stove pipe is a connector pipe that links wood stoves to insulated chimneys. This system features a black aluminized steel outer casing and heavy-gauge stainless steel inner liner. 1/4 in air space between inner and outer pipes provides great insulating value. 6 in clearance to combustibles. Three metal screws supplied with each length. For installed length, subtract 1-3/8 in per joint. Listed to ULC S641 and UL 103 standards.Unit: EA
Type L Pellet Vent to Selkirk Insulated Chimney Adapters are for use in connecting a Model VP Vent System into an existing Selkirk Chimney system.Unit: EA
Round collar fits lower end of suspended insulated chimney pipe to provide finished appearance. Used to attach T-DSA Smoke Pipe Adapter to lower end of chimney or to insulated Tee.Unit: EA
Type L pellet vent wall thimble must be used in all thru-the-wall installations involving combustible construction. UL listed.Unit: EA
Type L vent systems for pellet stove applications. For use in accommodating unusual offsets and configurations. Up to 90 deg maximum. Rated for flue temperatures up to 570 deg F. Model VP may be...
Type L vent systems for pellet stove applications. For use in accommodating unusual offsets and configurations. Up to 90 deg maximum. Rated for flue temperatures up to 570 deg F. Model VP may be installed with a minimum 1 in air space clearance to combustible surfaces, framing lumber, drywall and plywood. UL listed.Unit: EA
Used to trim the ceiling when a chimney is supported from above and extended down into room. Also used in conjunction with firestop/joist shield.Unit: EA
Selkirk SURE-TEMP Premium Roof Flashing, Aluminum, Galvanized, 24-3/4 in OAL, 21 in OAW, Suitable for: 7 x 12 in Dia PipeUnit: EA
Used to adjust pipe to desired length. Adjustable from 12 to 18 in, eliminating the need to cut pipe. Includes finishing band. For installed length, subtract 1-3/8 in per joint.Unit: EA
Selkirk Firestop Spacer, Specifications: 6 in Size, SteelUnit: EA
Used to start chimneys indoors or outdoors using a wall support assembly or a masonry pier. A length of insulated chimney pipe is attached to the tee snout, using a Locking Band, to pass safely...
Used to start chimneys indoors or outdoors using a wall support assembly or a masonry pier. A length of insulated chimney pipe is attached to the tee snout, using a Locking Band, to pass safely through combustible walls. An insulated tee cap is included which can be removed from bottom opening for inspection and cleanout. Maximum height of chimney which can be supported by an insulated tee is 50 ft.Unit: EA
Used along the wall to provide for 2 in clearance and assure stability. Useful for suspending offsets. Required at 8 ft or closer intervals to stabilize the chimney, wherever it is supported along a...
Used along the wall to provide for 2 in clearance and assure stability. Useful for suspending offsets. Required at 8 ft or closer intervals to stabilize the chimney, wherever it is supported along a vertical wall.Unit: EA
Used whenever there is a need to stabilize the chimney above the roof level. The purpose of the bracing is to hold the chimney against wind load and to prevent damage from static and sliding snow....
Used whenever there is a need to stabilize the chimney above the roof level. The purpose of the bracing is to hold the chimney against wind load and to prevent damage from static and sliding snow. It should be used, at a midpoint on the chimney. Bracket adjusts from 4 to 6 ft.Unit: EA
Can be used for fixed offsets of 15 deg slope or in pairs for offsets adjustable from zero to 30 deg slope. Greater angles are prohibited by UL standard 103 and by the terms of the product listing....
Can be used for fixed offsets of 15 deg slope or in pairs for offsets adjustable from zero to 30 deg slope. Greater angles are prohibited by UL standard 103 and by the terms of the product listing. Required locking bands (2 packaged with each elbow kit) allow 360 deg rotation and lock the components together in place at the exact offset required. Insulated elbows can be used at the same 2 in air space clearance as chimney sections. Includes 2 elbows, 2 locking bands and interior...
Three basic chimney kit is designed around one of the standard support systems.Unit: EA
Selkirk Trim Plate, Black, Dimensions: 3 in DiaUnit: EA