Account
My Items
OR
Zinc die-cast. Indoor or outdoor applications. Use to reduce the entry size of a run of threaded conduit. UL listed.Unit: BAG 1
Halex Clamp Connector, 3/8 in Trade, Zinc, 1-3/16 in Length, 1-3/16 in Width, 41/64 in Height, Suitable for: #14/2, 12/2, 12/3 AWG or 2 #14/2 AWG Non-Metallic Cable or 0.3 to 0.56 in Dia Flex...
Halex Clamp Connector, 3/8 in Trade, Zinc, 1-3/16 in Length, 1-3/16 in Width, 41/64 in Height, Suitable for: #14/2, 12/2, 12/3 AWG or 2 #14/2 AWG Non-Metallic Cable or 0.3 to 0.56 in Dia Flex CordUnit: BX100
Zinc die-cast. Indoors or outdoors. Use as a wire pulling elbow to facilitate wire pulling through a sharp bend in a run of threaded Rigid or IMC conduit. Removable cover provides easy access to...
Zinc die-cast. Indoors or outdoors. Use as a wire pulling elbow to facilitate wire pulling through a sharp bend in a run of threaded Rigid or IMC conduit. Removable cover provides easy access to wiring. UL listed. Bulk packed.Unit: EA
Unit: PK 50
Use to allow a 90 deg change of direction in a run of rigid or IMC conduit. UL listed.Unit: EA
Zinc die-cast. Use to connect EMT conduit to steel outlet box, load center or other metal enclosure. UL approved.Unit: EA
Zinc die-cast. Rounded surface prevents damage to insulation. Thermoplastic liner rated at 150 deg F. Indoor or outdoor use. Use with locknut to terminate service conduit to a cabinet. Lug provided...
Zinc die-cast. Rounded surface prevents damage to insulation. Thermoplastic liner rated at 150 deg F. Indoor or outdoor use. Use with locknut to terminate service conduit to a cabinet. Lug provided for bonding jumper to a neutral bus bar. UL listed and CSA certified.Unit: EA
Halex Conduit Coupling, 1/2 in Trade, Screw Connection, Zinc-Plated, 1.81 in Length, 0.92 in ODUnit: EA
Halex Terminal Adapter, 3/4 in Trade, Male Connection, PVC, 5 in LengthUnit: BAG 5
High-impact thermoplastic. Flame retardant to 105 deg C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire...
High-impact thermoplastic. Flame retardant to 105 deg C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL listed and CSA approved.Unit: EA
Aluminum, indoor or outdoor. Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. With cover and gasket. UL...
Aluminum, indoor or outdoor. Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. With cover and gasket. UL approved. Tray boxed.Unit: EA
Use to join two lengths of EMT conduit together. Zinc. UL, CSA Approved.Unit: EA
Indoor or outdoor applications. To support EMT conduit.Unit: BAG 4
Zinc die-cast. Use to connect EMT conduit to a metal outlet box or enclosure where an offset is desired. UL approved.Unit: BX10
Indoor or outdoor applications. To support EMT conduit.Unit: BAG 2
Aluminum, indoor or outdoor. Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. With cover and gasket. UL Approved.Unit: EA
Steel, use to secure service entrance cable (SEU, SER) to wood, masonry or similar surface.Unit: BX 25
Use to connect S, SO, ST, SJ, SJO and SJT cord to a steel outlet box or other metal enclosure. UL approved and CSA certified.Unit: BAG 2
Halex Reducing Washer, Steel, 1.73 in ID, 3 in OD, 0.0315 in ThicknessUnit: EA
Copper-free die cast aluminum. Indoors or outdoors. Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. UL...
Copper-free die cast aluminum. Indoors or outdoors. Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. UL approved. Tray boxed.Unit: EA
Use to join two lengths of EMT conduit together. Zinc. UL, CSA approved.Unit: EA
Steel, indoor or out. Use to join threaded Rigid or IMC conduit together. UL listed.Unit: EA
Made of steel, fully threaded. Indoor or outdoor. Use to connect two steel outlet boxes or other metal enclosures or to extend a length of threaded Rigid or IMC conduit. Bulk packed.Unit: EA
Indoor or outdoor applications. Use to secure rigid or I.M.C. conduit to wood, masonry or similar surfaces.Unit: BAG 4