Works as a sacrificial metal to protect cooler cabinet and parts. Unique anode tray design keeps anode above metal cooler bottom and allows anode to degrade evenly on all sides.Unit: CD
Controls scale build-up and corrosion in coolers. Special formula holds minerals in suspension by raising the solubility level of the water. Reduces mineral build-up on pads must be used with a...
Controls scale build-up and corrosion in coolers. Special formula holds minerals in suspension by raising the solubility level of the water. Reduces mineral build-up on pads must be used with a bleed off kit or PowerClean purge pump to flush suspended minerals.Unit: EA
A time release formula that controls unpleasant odors from algae and bacteria in evaporative coolers and neutralizes odor in cooler water to freshen the air. Not for potable (drinkable) water.Unit:...
A time release formula that controls unpleasant odors from algae and bacteria in evaporative coolers and neutralizes odor in cooler water to freshen the air. Not for potable (drinkable) water.Unit: EA
A time release formula that controls unpleasant odors from algae and bacteria in evaporative coolers and neutralizes odor in cooler water to freshen the air, not for potable (drinkable) water.Unit:...
A time release formula that controls unpleasant odors from algae and bacteria in evaporative coolers and neutralizes odor in cooler water to freshen the air, not for potable (drinkable) water.Unit: EA
Controls scale build-up and corrosion in coolers, special formula holds minerals in suspension by raising the solubility level of the water. Reduces mineral build-up on pads must be used with a...
Controls scale build-up and corrosion in coolers, special formula holds minerals in suspension by raising the solubility level of the water. Reduces mineral build-up on pads must be used with a bleed off kit or PowerClean purge pump to flush suspended minerals.Unit: EA
Variable pulleys must be opened 2-1/2 to 5 full turns, depending on air resistance or motor will overheat. If motor cycles (stops and starts due to over-heating), open variable pulley until motor...
Variable pulleys must be opened 2-1/2 to 5 full turns, depending on air resistance or motor will overheat. If motor cycles (stops and starts due to over-heating), open variable pulley until motor stops cycling. If cycling persists when pulley is fully opened, you must use the next size smaller pulley. Always use pulley size recommended by cooler manufacturer.Unit: EA
Variable pulleys must be opened 2-1/2 to 5 full turns, depending on air resistance or motor will overheat. If motor cycles, open variable pulley until motor stops cycling. If cycling persists when...
Variable pulleys must be opened 2-1/2 to 5 full turns, depending on air resistance or motor will overheat. If motor cycles, open variable pulley until motor stops cycling. If cycling persists when pulley is fully opened, you must use the next size smaller pulley. Always use pulley size recommended by cooler manufacturer.Unit: EA
Variable pulleys must be opened 2-1/2 to 5 in full turns, depending on air resistance or motor will overheat. If motor cycles, open variable pulley until motor stops cycling. If cycling persists...
Variable pulleys must be opened 2-1/2 to 5 in full turns, depending on air resistance or motor will overheat. If motor cycles, open variable pulley until motor stops cycling. If cycling persists when pulley is fully opened, you must use the next size smaller pulley. Always use pulley size recommended by cooler manufacturer.Unit: EA
Dial Blower Pulley, 10 in OD, 3/4 in Dia Bore, Zinc, 1 -Groove, For: Evaporative Cooler Purge SystemsUnit: EA
Dial Blower Pulley, 12 in OD, 3/4 in Dia Bore, Zinc, 1 -Groove, For: Evaporative Cooler Purge SystemsUnit: EA
Dial Pillow Block Bearing, Dimensions: 5/8 in Dia, Suitable for: Evaporative Cooler Purge SystemsUnit: EA
Dial Pillow Block Bearing, Dimensions: 3/4 in Dia, Suitable for: Evaporative Cooler Purge SystemsUnit: EA