Indoor or outdoor use. Use to secure rigid or IMC conduit to wood, masonry or similar surfaces where greater load bearing is required. UL Listed, CSA Approved.Unit: EA
Indoor or outdoor applications. Use in an overhead service entrance. Cap mounts on top of PVC, Rigid or IMC conduit. Serves as a connecting point for the service entrance wires. Bulk packed. PVC...
Indoor or outdoor applications. Use in an overhead service entrance. Cap mounts on top of PVC, Rigid or IMC conduit. Serves as a connecting point for the service entrance wires. Bulk packed. PVC Service entrance cap, 2 in.Unit: EA
Halex Reducing Washer, Steel, 1.11 in ID, 2.44 in OD, 0.0315 in ThicknessUnit: EA
Steel, use to secure service entrance cable (SEU, SER) to wood, masonry or similar surface.Unit: BAG 6
Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a...
Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements.Unit: EA
To connect EMT conduit together to allow for 90 deg bends. UL listed.Unit: EA
Fits #14/2, #14/3, #12/2, #10/2, #10/3 NM cable. Snap-in, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal...
Fits #14/2, #14/3, #12/2, #10/2, #10/3 NM cable. Snap-in, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL listed, CSA certified.Unit: BAG10
Steel, indoor or out. Use to join threaded Rigid or IMC conduit together. UL listed.Unit: EA
Indoor or outdoor applications. To support EMT conduit.Unit: BAG 4
Halex Conduit Nipple, 1/2 in Trade, Threaded Connection, SteelUnit: BAG
Zinc die-cast. Removable steel cover facilitates wire pulling. Use to connect EMT conduit together at an inside corner. UL listed, CSA approved. Tray boxed.Unit: EA
Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. With cover and gasket. UL approved. Tray boxed.Unit: EA
Halex Clamp Connector, 3/4 to 1 in Trade, Steel, Galvanized, 1-3/4 in Length, 3/4 in Width, 1-21/32 in Height, Suitable for: 0.2 to 0.85 in Dia Non-Metallic CableUnit: BAG 5
Zinc die-cast. Use as an offset connector between two enclosures. Offsets the axis of the raceway 3/4 in. UL approved.Unit: EA
Halex Clamp Connector, 3/8 in Trade, Zinc, 1-3/16 in Length, Suitable for: #14/2, 12/2, 12/3 AWG or 2 #14/2 AWG Non-Metallic CableUnit: BAG 5
Halex Conduit Coupling, 3/4 in Trade, Slip Joint Connection, PVCUnit: BAG
Steel, indoor or out. Use to join threaded Rigid or IMC conduit together. UL listed.Unit: BAG 1
Steel, use to secure BX cable to wood, masonry or similar surface.Unit: BAG10
Zinc die-cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.Unit: BAG 1
Aluminum, indoor or outdoor. Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. With cover and gasket. UL...
Aluminum, indoor or outdoor. Use to gain access to the interior of a raceway for wire pulling, splicing (with limitations as specified by the NEC) and maintenance. With cover and gasket. UL Approved.Unit: EA
Push-in style with captive locking wedge. Rigid PVC. Excellent strain relief and insulation. In a dry location, use to secure #14 to #10 non-metallic sheathed cable to steel outlet box or other...
Push-in style with captive locking wedge. Rigid PVC. Excellent strain relief and insulation. In a dry location, use to secure #14 to #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. Fits NM cable #14/2 to #10/3. Fits 1/2 in knockouts. UL, CSA listed.Unit: BAG 5
Concretetight and raintight. Use to connect EMT conduit to steel outlet box, load center or other metal enclosure in a wet location.Unit: EA
Halex Clamp Connector, 1-1/2 in Trade, Zinc, 2-61/64 in Length, 2 in Width, 1 in Height, Suitable for: 0.835 to 1.52 in Dia Non-Metallic Cable, Flex Cords, Multi-Flex Cords or (2) Conductor 4/0 SE...
Halex Clamp Connector, 1-1/2 in Trade, Zinc, 2-61/64 in Length, 2 in Width, 1 in Height, Suitable for: 0.835 to 1.52 in Dia Non-Metallic Cable, Flex Cords, Multi-Flex Cords or (2) Conductor 4/0 SE CablesUnit: EA
Use to cover exposed knock-out holes in steel outlet boxes and other metal enclosures.Unit: EA